NHTSA ID Number: 10144202
Manufacturer Communication Number: SSM 47402
Summary
When performing diagnostics for DTCs P2201, P2452, P2459, P246C and/or P2463, a manual regeneration and diesel particulate filter (DPF) parameter reset using the appropriate scan tool may need to be performed. To perform the manual regeneration, go to the Toolbox tab > Powertrain > Service Functions > Diesel Particulate Regeneration System > DPF Manual Regeneration. The scan tool may indicate that a regeneration of the DPF is not recommended at this time, selecting YES on this screen will allow the regeneration process to complete. To perform the DPF parameter reset, go to the Toolbox tab > Powertrain > Service Functions > Diesel Particulate Regeneration System > DPF Parameter Reset.
46 Affected Products
Vehicles
| FORD | F-250 SD | 2011-2018 |
| FORD | F-350 SD | 2011-2018 |
| FORD | F-450 SD | 2011-2017 |
| FORD | F-550 SD | 2011-2017 |
| FORD | F-650 SD | 2011-2018 |
| FORD | F-750 SD | 2011-2018 |
SSM 47402
- Meets GM Original Equipment specifications to be approved for use in GM vehicles as well as in non-GM diesel vehicles that have an SCR (Selective Catalytic Reduction) system to meet regulated NOx emissions (Based on EPA certification testing. Your actual emissions will vary based on several factors including temperature, terrain, and driving conditions).
- High quality formula is made from high purity urea and deionized water.
- Meets API regulations and ISO 22241 standard for purity and concentration
- Nozzles sold separately
- Blue Def DEF002-2PK Diesel Exhaust Fluid, 2.5 Gallon, 2 Pack
Last update on 2026-05-30 / Affiliate links / Images from Amazon Product Advertising API